Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified

Product Details
Customization: Available
Type: Surgical Supplies Materials
Material: ABS
Still deciding? Get samples of US$ 8/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
70
Year of Establishment
2020-12-10
  • Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
  • Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
  • Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
  • Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
  • Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
  • Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Soudon Service
  • Instructions
  • Detailed Photos
  • FAQ
Overview

Basic Info.

Model NO.
SD-03-M230-10A
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
Two Years
Group
Adult
Logo Printing
With Logo Printing
Loop Width
10mm
Length
230cm
Sheath Od
2.3mm
Shape
Hexagon
Model
SD-03-M230-10A
Transport Package
Cartoon
Specification
25mm
Trademark
Soudon
Origin
China
HS Code
9018903090
Production Capacity
10000000

Product Description

Product Description

Product name: Disposable Polypectomy Snares

[Structural Composition] Disposable polypectomy snare consists of shredded wire, adapter tube, pull cable, sheath tube, outer sheath tube, catheter, wheel, fixing tube, clamp block, electrode, sliding handle and handle.
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified

 1 Shredded 2 Adapter Tube 3 Cable 4 Sheath Tube 5 Outer Sheath Tube 6 Catheter 7 Wheel 8 Fixed Tube 9 Clamp Block 10 Electrode 11 Sliding Handle 12 Handle




There are Hexagon,Oval and Crescent types to choose from according to clinical requirement.
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified


you also can choose the width according your need,such 10mm,25mm,30mm,35mm

Next,let's check the physical map


as shown in the figure, the product link is Hexagon type 


[Application]In medical institutions, this product is used in conjunction with endoscopes and high-frequency generators for the removal of polyps in the digestive tract.
 
 
Product Parameters
Part No. Sheath OD (mm) Effective Length (cm) Loop Width (mm) Shape
SD-03-M230-10A 2.3 230 10 Oval Type A
SD-03-M230-25A * 2.3 230 25 Oval Type A
SD-03-M230-30A 2.3 230 30 Oval Type A
SD-03-M230-35A 2.3 230 35 Oval Type A
SD-03-M180-10A 2.3 180 10 Oval Type A
SD-03-M180-25A 2.3 180 25 Oval Type A
SD-03-M180-30A 2.3 180 30 Oval Type A
SD-03-M180-35A 2.3 180 35 Oval Type A
SD-03-M230-25B 2.3 230 25 Hexagon Type B
SD-03-M180-25B 2.3 180 25 Hexagon Type B
SD-03-M230-35T * 2.3 230 35 Shield Type T
SD-03-M180-35T 2.3 180 35 Shield Type T


 
Soudon Service

OEM:your company logo or name,color,detail specification of product
Quality: As long as there is damage due to non-human reasons, we provide free replacement
Support: We will try our best to provide the documents needed by suppliers to support the cooperation



 
Instructions

1. When removing a device from its packaging, unroll it and pay special attention to visually inspecting it for kinks, bends, or shattering. Do not use if abnormalities are found that may prevent its normal use.
2. Check the connecting wires, the cables must not have kinks, bends, broken or exposed wires, so that the power can be turned on normally, if there is any abnormality, the connecting wires should not be used.
3. Fully retract and extend the snare to verify that the product operates smoothly. Rotate the handle to confirm that the shreds can be turned flexibly.
4. In the case of turning off the power of high-frequency electrical equipment, perform a trial connection operation between the equipment and the device. Connect the connecting wire firmly to the electrode connection plug of the handle of the snare and the high-frequency electrical equipment. According to the requirements of the high-frequency electrical equipment manufacturer, place the patient return electrode and connect it to the high-frequency electrical equipment.
5. When the polyp is in the field of view of the endoscope, fully retract the snare into the sheath, and then slowly insert the sheath into the working channel of the endoscope until the front end of the snare protrudes out of the endoscope. WARNING: To ensure patient safety, power to high frequency electrical equipment should be disconnected until the snare is fully positioned around the polyp.
6. Push the snare slide handle until the snare shred is fully out of the sheath and place the shred around the polyp to be resected. In order to successfully capture polyps, the cutting plane should be perpendicular to the polyp pedicle. When not vertical, the handle can be rotated to adjust the angle of the snare plane until it is vertical. WARNING: To ensure patient safety, power to the HF generator device should be disconnected until the snare is fully positioned around the polyp.
7. Follow the manufacturer's instructions for the high-frequency electric generator equipment, turn on the power, and verify the desired setting parameters.
8. Perform a polypectomy to cut the polyp.
9. After the polypectomy is completed, turn off the power of the high-frequency electric generator. Insert the snare into the sheath and withdraw it from the endoscope.
10. Collect polyps, prepare or dispose of samples according to the treatment methods of the hospital where you are located.
11. After the operation is completed, pull out the connection wire from the snare electrode connection plug, and dispose of this product according to the guidelines of the hospital's biohazardous medical waste.
12. Disconnect the connecting wire from the high-frequency electrical equipment, and wipe off all foreign objects on the connecting wire with a damp cloth. Store loosely coiled.

 
Detailed Photos

Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified

 Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA QualifiedCold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA QualifiedCold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified




ABOUT SOUDON:
Zhejiang Shouding Medical Technology Co., Ltd. is an emerging brand company specializing in the R&D, production and sales of endoscopic minimally invasive interventional high-value medical devices. Established in December 2020, it is located in the world-famous beautiful West Lake - Hangzhou City.
The company covers an area of nearly 4,500 square meters, with standardized workshops, 100,000-level purification workshops and 10,000-level laboratories, equipped with advanced production and testing equipment.
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified


 
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified

Cold Polypectomy Snare with a Small Snare with 9mm Opening Diameter and a Thin Thread (monofilament) of 0.3mm with CE/FDA Qualified
FAQ

Q1: Are you the factory or trading company?
A1: We are a ODM&OEM manufacturer of endoscope accessories like Endoscopic Polypectomy Snares.

Q2: Can i order one or two pieces as sample to test in first?
A2: Of course. please check with us if we have this Endoscopic Polypectomy Snares in stock or not at first.

Q3: How can i know the shipping cost?
A3: After you confirm the model and order quantity, we will check the cheapest shipping cost for you.

Q4: What certificate do you have?
A4: We have MDR CFDA,SGS and FSC for most of our surgical product.

Q5: Can I be your distributor?
A5: Of course, please contact with us for more details.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier