CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp

Product Details
Customization: Available
Type: Surgical Supplies Materials
Material: ABS
Still deciding? Get samples of US$ 8/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
70
Year of Establishment
2020-12-10
  • CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
  • CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
  • CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
  • CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
  • CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
  • CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Soudon Service
  • Instructions
  • Detailed Photos
  • Company Profile
  • Recommended Products
  • FAQ
Overview

Basic Info.

Model NO.
SD-03-M230-25b
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
Two Years
Group
Adult
Logo Printing
With Logo Printing
Loop Width
25mm
Length
230cm
Sheath Od
2.3mm
Shape
Hexagon
Model
SD-03-M230-25b
Transport Package
Cartoon
Specification
25mm
Trademark
Soudon
Origin
China
HS Code
9018903090
Production Capacity
10000000

Product Description

Product Description

Endoscopic Single Use hot Cut Polypectomy Snare Polyp Snare for ESD Surgery With ISO MDR CE with Power on Handle

Endoscopic Polypectomy Snares Features:

The rotatable endoscope hot snare polypectomy hexagon shape has Rotation function improves polyp retrieval efficiency.
A variety of different shapes and different specifications are suitable for different clinical needs.
Using nickel-titanium alloy wire, it is suitable for the treatment of complex location lesions, and it is not deformed after being bent for many times.
Coil hardness is moderate, recovery is good, easy to open and close.
[Structural Composition] Disposable polypectomy snare consists of shredded wire, adapter tube, pull cable, sheath tube, outer sheath tube, catheter, wheel, fixing tube, clamp block, electrode, sliding handle and handle.
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp

 1 Shredded 2 Adapter Tube 3 Cable 4 Sheath Tube 5 Outer Sheath Tube 6 Catheter 7 Wheel 8 Fixed Tube 9 Clamp Block 10 Electrode 11 Sliding Handle 12 Handle




There are Hexagon,Oval and Crescent types to choose from according to clinical requirement.
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp


you also can choose the width according your need,such 10mm,25mm,30mm,35mm

Next,let's check the physical map


as shown in the figure, the product link is Hexagon type 


[Application]In medical institutions, this product is used in conjunction with endoscopes and high-frequency generators for the removal of polyps in the digestive tract.
 
 
Product Parameters

 
Part No. Sheath OD (mm) Effective Length (cm) Loop Width (mm) Shape
SD-03-M230-10A 2.3 230 10 Oval Type A
SD-03-M230-25A * 2.3 230 25 Oval Type A
SD-03-M230-30A 2.3 230 30 Oval Type A
SD-03-M230-35A 2.3 230 35 Oval Type A
SD-03-M180-10A 2.3 180 10 Oval Type A
SD-03-M180-25A 2.3 180 25 Oval Type A
SD-03-M180-30A 2.3 180 30 Oval Type A
SD-03-M180-35A 2.3 180 35 Oval Type A
SD-03-M230-25B 2.3 230 25 Hexagon Type B
SD-03-M180-25B 2.3 180 25 Hexagon Type B
SD-03-M230-35T * 2.3 230 35 Shield Type T
SD-03-M180-35T 2.3 180 35 Shield Type T
Soudon Service

OEM:your company logo or name,color,detail specification of product
Quality: As long as there is damage due to non-human reasons, we provide free replacement
Support: We will try our best to provide the documents needed by suppliers to support the cooperation

 
Instructions

1. When removing a device from its packaging, unroll it and pay special attention to visually inspecting it for kinks, bends, or shattering. Do not use if abnormalities are found that may prevent its normal use.
2. Check the connecting wires, the cables must not have kinks, bends, broken or exposed wires, so that the power can be turned on normally, if there is any abnormality, the connecting wires should not be used.
3. Fully retract and extend the snare to verify that the product operates smoothly. Rotate the handle to confirm that the shreds can be turned flexibly.
4. In the case of turning off the power of high-frequency electrical equipment, perform a trial connection operation between the equipment and the device. Connect the connecting wire firmly to the electrode connection plug of the handle of the snare and the high-frequency electrical equipment. According to the requirements of the high-frequency electrical equipment manufacturer, place the patient return electrode and connect it to the high-frequency electrical equipment.
5. When the polyp is in the field of view of the endoscope, fully retract the snare into the sheath, and then slowly insert the sheath into the working channel of the endoscope until the front end of the snare protrudes out of the endoscope. WARNING: To ensure patient safety, power to high frequency electrical equipment should be disconnected until the snare is fully positioned around the polyp.
6. Push the snare slide handle until the snare shred is fully out of the sheath and place the shred around the polyp to be resected. In order to successfully capture polyps, the cutting plane should be perpendicular to the polyp pedicle. When not vertical, the handle can be rotated to adjust the angle of the snare plane until it is vertical. WARNING: To ensure patient safety, power to the HF generator device should be disconnected until the snare is fully positioned around the polyp.
7. Follow the manufacturer's instructions for the high-frequency electric generator equipment, turn on the power, and verify the desired setting parameters.
8. Perform a polypectomy to cut the polyp.
9. After the polypectomy is completed, turn off the power of the high-frequency electric generator. Insert the snare into the sheath and withdraw it from the endoscope.
10. Collect polyps, prepare or dispose of samples according to the treatment methods of the hospital where you are located.
11. After the operation is completed, pull out the connection wire from the snare electrode connection plug, and dispose of this product according to the guidelines of the hospital's biohazardous medical waste.
12. Disconnect the connecting wire from the high-frequency electrical equipment, and wipe off all foreign objects on the connecting wire with a damp cloth. Store loosely coiled.


 
Detailed Photos
 
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal PolypCE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal PolypCE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
 
Company Profile
Zhejiang Soudon medical is an experienced manufacturer of endoscope accessories like endoscopic snare polypectomy etc for EMR,ESD and ERCP. With rich experience and many good review from global customers, we got MDR, ISO13485, CFDA and FSC certificates.

We are equipped with advanced manufacturing machineries and state-of-art testing instruments, our company has modern manufacturing facilities with 100,000 grade air-controlled workshops, 10,000 grade physical lab and chemical lab, and 100 grade sterile testing laboratory
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal PolypCE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp
Recommended Products
CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp

CE/FDA Approved Endoscopic Resection Standard Polypectomy Traps Medical Consumable Supply Disposable Polypectomy Snare for Emr Rectal Polyp

FAQ

Q1: Are you the factory or trading company?
A1: We are a ODM&OEM manufacturer of endoscope accessories like Endoscopic Polypectomy Snares.

Q2: Can i order one or two pieces as sample to test in first?
A2: Of course. please check with us if we have this Endoscopic Polypectomy Snares in stock or not at first.

Q3: How can i know the shipping cost?
A3: After you confirm the model and order quantity, we will check the cheapest shipping cost for you.

Q4: What certificate do you have?
A4: We have MDR CFDA,SGS and FSC for most of our surgical product.

Q5: Can I be your distributor?
A5: Of course, please contact with us for more details.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier