Product Description
Endoscopic Single Use hot Cut Polypectomy Snare Polyp Snare for ESD Surgery With ISO MDR CE with Power on Handle
Endoscopic Polypectomy Snares Features:
The rotatable endoscope hot snare polypectomy hexagon shape has Rotation function improves polyp retrieval efficiency.
A variety of different shapes and different specifications are suitable for different clinical needs.
Using nickel-titanium alloy wire, it is suitable for the treatment of complex location lesions, and it is not deformed after being bent for many times.
Coil hardness is moderate, recovery is good, easy to open and close.
[Structural Composition] Disposable polypectomy snare consists of shredded wire, adapter tube, pull cable, sheath tube, outer sheath tube, catheter, wheel, fixing tube, clamp block, electrode, sliding handle and handle.
1 Shredded 2 Adapter Tube 3 Cable 4 Sheath Tube 5 Outer Sheath Tube 6 Catheter 7 Wheel 8 Fixed Tube 9 Clamp Block 10 Electrode 11 Sliding Handle 12 Handle
There are Hexagon,Oval and Crescent types to choose from according to clinical requirement.
you also can choose the width according your need,such 10mm,25mm,30mm,35mm
Next,let's check the physical map
as shown in the figure, the product link is Hexagon type
[Application]In medical institutions, this product is used in conjunction with endoscopes and high-frequency generators for the removal of polyps in the digestive tract.
Product Parameters
Part No. |
Sheath OD (mm) |
Effective Length (cm) |
Loop Width (mm) |
Shape |
SD-03-M230-10A |
2.3 |
230 |
10 |
Oval Type A |
SD-03-M230-25A * |
2.3 |
230 |
25 |
Oval Type A |
SD-03-M230-30A |
2.3 |
230 |
30 |
Oval Type A |
SD-03-M230-35A |
2.3 |
230 |
35 |
Oval Type A |
SD-03-M180-10A |
2.3 |
180 |
10 |
Oval Type A |
SD-03-M180-25A |
2.3 |
180 |
25 |
Oval Type A |
SD-03-M180-30A |
2.3 |
180 |
30 |
Oval Type A |
SD-03-M180-35A |
2.3 |
180 |
35 |
Oval Type A |
SD-03-M230-25B |
2.3 |
230 |
25 |
Hexagon Type B |
SD-03-M180-25B |
2.3 |
180 |
25 |
Hexagon Type B |
SD-03-M230-35T * |
2.3 |
230 |
35 |
Shield Type T |
SD-03-M180-35T |
2.3 |
180 |
35 |
Shield Type T |
Soudon Service
OEM:your company logo or name,color,detail specification of product
Quality: As long as there is damage due to non-human reasons, we provide free replacement
Support: We will try our best to provide the documents needed by suppliers to support the cooperation
Instructions
1. When removing a device from its packaging, unroll it and pay special attention to visually inspecting it for kinks, bends, or shattering. Do not use if abnormalities are found that may prevent its normal use.
2. Check the connecting wires, the cables must not have kinks, bends, broken or exposed wires, so that the power can be turned on normally, if there is any abnormality, the connecting wires should not be used.
3. Fully retract and extend the snare to verify that the product operates smoothly. Rotate the handle to confirm that the shreds can be turned flexibly.
4. In the case of turning off the power of high-frequency electrical equipment, perform a trial connection operation between the equipment and the device. Connect the connecting wire firmly to the electrode connection plug of the handle of the snare and the high-frequency electrical equipment. According to the requirements of the high-frequency electrical equipment manufacturer, place the patient return electrode and connect it to the high-frequency electrical equipment.
5. When the polyp is in the field of view of the endoscope, fully retract the snare into the sheath, and then slowly insert the sheath into the working channel of the endoscope until the front end of the snare protrudes out of the endoscope. WARNING: To ensure patient safety, power to high frequency electrical equipment should be disconnected until the snare is fully positioned around the polyp.
6. Push the snare slide handle until the snare shred is fully out of the sheath and place the shred around the polyp to be resected. In order to successfully capture polyps, the cutting plane should be perpendicular to the polyp pedicle. When not vertical, the handle can be rotated to adjust the angle of the snare plane until it is vertical. WARNING: To ensure patient safety, power to the HF generator device should be disconnected until the snare is fully positioned around the polyp.
7. Follow the manufacturer's instructions for the high-frequency electric generator equipment, turn on the power, and verify the desired setting parameters.
8. Perform a polypectomy to cut the polyp.
9. After the polypectomy is completed, turn off the power of the high-frequency electric generator. Insert the snare into the sheath and withdraw it from the endoscope.
10. Collect polyps, prepare or dispose of samples according to the treatment methods of the hospital where you are located.
11. After the operation is completed, pull out the connection wire from the snare electrode connection plug, and dispose of this product according to the guidelines of the hospital's biohazardous medical waste.
12. Disconnect the connecting wire from the high-frequency electrical equipment, and wipe off all foreign objects on the connecting wire with a damp cloth. Store loosely coiled.
Detailed Photos
Company Profile
Zhejiang Soudon medical is an experienced manufacturer of endoscope accessories like endoscopic snare polypectomy etc for EMR,ESD and ERCP. With rich experience and many good review from global customers, we got MDR, ISO13485, CFDA and FSC certificates.
We are equipped with advanced manufacturing machineries and state-of-art testing instruments, our company has modern manufacturing facilities with 100,000 grade air-controlled workshops, 10,000 grade physical lab and chemical lab, and 100 grade sterile testing laboratory
Recommended Products
FAQ
Q1: Are you the factory or trading company?
A1: We are a ODM&OEM manufacturer of endoscope accessories like Endoscopic Polypectomy Snares.
Q2: Can i order one or two pieces as sample to test in first?
A2: Of course. please check with us if we have this Endoscopic Polypectomy Snares in stock or not at first.
Q3: How can i know the shipping cost?
A3: After you confirm the model and order quantity, we will check the cheapest shipping cost for you.
Q4: What certificate do you have?
A4: We have MDR CFDA,SGS and FSC for most of our surgical product.
Q5: Can I be your distributor?
A5: Of course, please contact with us for more details.